Pipe sleeve type RK I
Pipe sleeve, type RK I Plus
PIPSLEV-M-300MM
Art.-no. 0893304300
EAN 4045989070787
		
			
			
				
Individual price display after login
				
			
		
		
				
	
	
					
				
Exclusively for trade customers
		Register now and access more than 125,000 products
Fire protection sleeve suitable for retrofitting
 
- Synthetic rubber insulated pipes (insulation ≤ 43 mm) up to 250 mm in diameter can be routed through the sleeve
 - Space-saving installation thanks to low sleeve height
 - Can be installed in extremely tight spaces
 - No loose fastening parts
 - No pre-assembly
 - Few attachment points
 - Additional acoustic insulation possible
 - Can even be used at high temperatures
 - Moisture does not impair functionality
 - Control cables for pneumatic post systems may be routed through
 - Solid foam withstands the pressure of firefighting water
 - Zero spacing between sleeves permissible
 - Entirely maintenance-free
 - Extremely easy to use
 - Can be reused after removal
 
Proof of Performance
Wall and ceiling ducts fire-resistant Z-19.53-2379
Notice
- Select the correct sleeve for the outer diameter of the pipe being protected
 - In difficult installation situations, a sleeve up to three sizes larger can also be selected (applies up to a pipe outside diameter of 110 mm)
 - The sleeve (up to a sleeve diameter of 200 mm) can be mortared into position without using an anchor by bending the retaining brackets
 
Pipe sleeve type RK I Plus on request, special order:
- Outside diameter 225 mm - inside diameter 239 mm - medium pipe range from 201 to 225 mm
 - Outside diameter 250 mm - inside diameter 264 mm - medium pipe range from 226 to 250 mm
 
| The following dimensions must be observed when installing the fire protection sleeve: | |||||
| External diameter of plastic pipe from 32 to 315 mm. | |||||
| Cuff diameter mm | ≤ 200 | > 200–≤280 | > 280–≤315 | ≤ 280 | > 280–≤315 | 
| Minimum thickness of component for | Wall bulkhead R 90 | Ceiling bulkhead R 90 | |||
| Masonry according to DIN 1053-1 | 100 mm | 150 mm | 200 mm | – | – | 
| Concrete, reinforced concrete according to DIN 1045 | 100 mm | 150 mm | 200 mm | 150 mm | 200 mm | 
| Light partition walls in accordance with DIN 4102 | 100 mm | – | – | – | – | 
Close the remaining gap between the plastic pipe and the reveal. Place the folded boot around the plastic tube.
WÜTOP sleeve Attach the cuff with a dowels or screw in the bent tabs.
Affix ID plate
Wall and ceiling ducts fire-resistant Z-19.53-2379
		Product information
	
	
		
	
	
		
	Datasheets(X)
Application area
For use in system [A] + [C] + [F]
- Combination partition [A]
 - Fire partition W combination [C]
 - Fire protection sleeve [F]
 
- For wall and ceiling ducts
 - Fire resistance for 90 minutes, fire-resistant
 - For flammable pipes with outer diameters up to 315 mm
 - For multi-layer composite pipes and pipe systems with protective pipe (double pipe system)
 - For pneumatic tube transport systems and vacuum cleaner lines
 - For masonry and concrete ceilings and walls; also for light partition walls
 - For fire-resistant walls from 100 mm: One sleeve on each side of the wall
 - For fire-resistant ceilings from 150 mm: One sleeve on the ceiling underside
 - Approval also permits partitioning of beverage hoses
 
DN nominal width  | DN 300  | 
Internal diameter  | 314 mm  | 
Outer diameter  | 403 mm  | 
Height  | 51.0 mm  | 