Female thread anchor with metric thread for secure anchoring in hollow-core prestressed concrete ceilings. With technical approval. Steel, zinc-plated
  • Screws or threaded rods can be used

  • The anchor can also be mounted outside the cavity axis, up to 50 mm from the prestressed strand – maximum flexibility

  • Quick, easy installation – no special tool required

  • Immediate load-bearing capacity – no waiting
Proof of Performance
  • DIBt National technical approval Z-21.1-1832

  • Fire resistance (base material: concrete C45/55 or C50/60): R30, R60, R90, R120: DIBt National technical approval Z-21.1-1832, fire protection test report no. (3526/3426)
Notice
  • The cone is separated from the expansion sleeve when the screw or hexagon nut is tightened. - Important: At least three screw/nut rotations are required. Applying the installation torque pulls the cone into the expansion sleeve and expands it

  • Anchoring is only permissible in hollow-core prestressed concrete ceilings with a hollow space width that does not exceed 4.2 times the web width (bH <= 4.2 x bSt)
Application area

Key:


tfi x = thickness of the attachment


du = mirror thickness


bH = cavity width


bSt = web width


sSp = axis distance to pre-stressed strand


c = edge distance


Tinst = installation torque

Key:


tfi x = thickness of the attachment


du = mirror thickness


bH = cavity width


bSt = web width


sSp = axis distance to pre-stressed strand


c = edge distance


Tinst = installation torque

Create the drill hole

Set anchor in place

Mount component

At least three rotations of the screw - Cone separates from sleeve

Apply installation torque

Installation status

  • DIBt National technical approval Z-21.1-1832

  • Fire resistance (base material: concrete C45/55 or C50/60): R30, R60, R90, R120: DIBt National technical approval Z-21.1-1832, fire protection test report no. (3526/3426)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Special fastener for anchoring in hollow-core prestressed concrete ceilings



Suitable for cavities and solid zones of hollow-core prestressed concrete ceilings



Fixing points and anchors in a redundant non-structural system with approval


  • Hollow-core prestressed concrete ceilings with concrete compressive strength class of C45/55 or B55

  • E.g. anchoring of lightweight ceiling coverings and suspended ceilings as well as for statically comparable anchoring up to 1.0 kN/sqm and the mounting of metal structures, brackets, cable conduits, pipes, ventilation lines, suspended ceilings etc.


W-HD can be used in dry indoor areas, e.g. homes, offices, schools, hospitals, retail outlets

Anchor diameter

10 mm

Sleeve length

40 mm

Required screw length (l s)

55 mm + thickness of the add-on part (t fix)

Required stud-bolt length (l B)

63 + thickness of the add-on part (t fix)

Nominal drill-bit diameter (d 0)

16 mm

Drill hole depth (h 0)

60 mm

Through-hole in the component to be connected (d f)

12 mm

Installation torque (T inst)

30 Nm

Material

Steel

Surface

Zinc plated

Performance data
Anchor diameter [mm]M6M8M10M12
Anchor pair3)
ccr ≥ [mm]150
Admissible load1)2)
Prestressed concrete hollow-core panels min. edge distance cmin ≥ 100 mm
Spacing scr ≥ 300 mm
Fadm [kN] ≥ C45/551)2)0,350,81,82,40,350,81,83,00,81,02,73,00,81,02,73,6
cmin ≥ [mm]100
Admissible load
Tensile, shear load and diagonal tensile force at every angle
Admissible load1)2)
Prestressed concrete hollow-core panels edge distance ccr ≥ 150 mm
Min. spacing smin
Fadm/anchor pair [kN] ≥ C45/551)2)0,71,42,63,90,71,42,64,81,12,04,84,81,22,04,85,7
smin ≥ [mm]7080100100708010010070801001007080100100
ccr ≥ [mm]150
Admissible load1)2)
Prestressed concrete hollow-core panels edge distance cmin ≥ 100 mm
Min. spacing smin
Fadm/anchor pair [kN] ≥ C45/551)2)0,351,252,353,20,351,252,3540,91,84,34,311,84,34,8
smin ≥ [mm]7080100100708010010070801001007080100100
cmin ≥ [mm]100
Admissible bending moment strength class 5.8Madm [Nm]-10,721,437,4
Admissible bending moment strength class 8.8Madm [Nm]4,417,134,259,8
(Fire resistance R30, R60, R90, R120 see fire protection test report no. 3526/3426) and gen. construction permit perm. no.: Z-21.1-1832
Mirror thicknessdu ≥ [mm]25304050253040502530405025304050
Spacing between individual anchors or anchor pairsscr ≥ [mm]300
Individual anchors
Admissible load
Tensile, shear load and diagonal tensile force at every angle
Admissible load1)2)
Prestressed concrete hollow-core panels edge distance ccr ≥ 150 mm
Spacing scr ≥ 300 mm
Fadm [kN] ≥ C45/551)2)0,70,92,02,90,70,92,03,60,91,23,03,61,01,23,04,3
Characteristic values
Nominal drill diameter4)d0 [mm]10121618
Drill hole depthh0 [mm]50556070
Through hole in the component being connecteddf ≤ [mm]791214
Installation torqueTinst = [Nm]10203040
Diameter of cutting edges4)dcut ≤ [mm]10,4512,516,518,5